Air to water heat pump

Specification

Heating

Nominal Capacity (min~max) 9.0 (3.5~12.0) kW
CoP (Nominal) 3.70
Tapping Capacity (Sanitary hot water) in:15°C out:40°C 270 litre 12 litre/min
Tapping Capacity (Sanitary hot water) in:15°C out:40°C 200 litre 16 litre/min

Cooling

Nominal Capacity (min~max) 8.0 (3.0~9.0)
CoP (Nominal) 2.87

Split system

Working range during heating with compressor (ambient temperature) -20 - +43°C
Working range during cooling (ambient temperature) +15 - +43°C
Max temperature flow line 65°C
Max temperature flow line, only use of compressor 58°C
Refrigerant quantity (R410A) 2.9 kg (included in FDCW100VNX)
Max length, refrigerant pipe 12m
Max height difference, refrigerant pipe 7m
Dimensions, refrigerant pipe Gas pipe: OD15.88 (5/8") Liquid pipe: OD9.52 (3/8")
Pipe connections Flare

HM270V (Indoor unit)

Immersion heater Max 9kW
Volume, total 270 litre ±5%
Volume, hot water coil 14 litre
Height 1760 mm (+20-50 mm, adjustable feet)
Width 600 mm
Depth 650 mm
Weight (without water in tank) 140 kg
Electrical connections 1Phase 230V / 3Phase 400V 50Hz

FDCW100VNX (Outdoor unit)

Height 845mm
Width 970mm
Depth 370mm (+80 mm with foot rail)
Weight 74kg

 

      Cooling (°C) Heating (°C)
Operation Conditions Water Temperature Inlet 12 40
Outlet 7 45
Outdoor Temperature 35 7