Air to water heat pump

Dimensions

Indoor unit (6HP)

 

Indoor unit (6HP)

MT500

Indoor unit (6HP)

Mark Item
XL3 Cold water G1 ext (1")
XL4 Hot water G1 ext (1")
XL8 External heat source in G1 int
XL9 External heat source out G1 int
XL23 Circulation supply 28mm
XL24 Circulation return 28mm

 

Outdoor unit (3.5HP)

Indoor unit (6HP)

Mark Item 3HP/HP 6HP
A Service valve connection (gas side) Ø15.88(5/8") (flare)
B Service valve connection (liquid side) Ø9.52(3/8") (flare)
C Pipe/cable draw-out hole    
D Drain discharge hole Ø20x3places
E Anchor bolt hole M10x4places
F Cable draw-out port Ø30x3places Ø30(front)
Ø45(side)
Ø50(back)

 

Notes:
(1) It must not be sorrounded by walls on the four sides.
(2) The Unit must be fixed with anchor bolts. An anchor bolt must not protrude more than 15mm
(3) Where the unit is subject to strong winds, lay it in such a direction that the blower ourlet
faces perpendicularly to the dominant wind direction
(4) Leave 1m or more space above the unit
(5) A wall in front of the blower outlet must not exceed the units height
(6) The model name label is attached on the lower right corner of the ront panel

 

Minimum installation space

 

3HP

Dimensions Examples of installation 1 2 3
L1   Open Open 500
L2 300 250 Open
L3 100 150 100
L4 250 250 250

 

3.5HP/6HP

Dimensions Examples of installation 1 2 3
L1   Open Open 500
L2 300 5 Open
L3 150 300 150
L4 5 5 5

 

Indoor unit (6HP)

Indoor unit (3HP, 3.5HP)

 

Indoor unit (3HP, 3.5HP)

Tank for indoor unit (6HP)

 

HT30

Indoor unit (6HP)

Mark Item
XL23 Circulation supply 28mm
XL24 Circulation supply 28mm

 

MT300

Indoor unit (6HP)

 

Outdoor unit (3HP)

Indoor unit (6HP)

 

Outdoor unit (6HP)

Indoor unit (6HP)